Load Banks Direct Logo Stationary Load Banks

%%SHORT%%
185 Manual or Automatic, Door Closed
%%SHORT%%
185 Manual or Automatic, Door Open
185L Auto Enclosed, Cell & Cable Site
185L Auto Panel Open, Cell & Cable Site
 
Stationary Load Banks, Single & Three Phase,
LBD--STATIONARY-PRTGRP (4622)
10 kW to 6,200 kW, 60 & 50 Hertz. Also sold on GSA GS-07F-5964R
Built to Order
30 days from order date
Ship Via
FEDEX Ground Freight
List Price
You Save
Our Price
Select Options Below
Plus Options
Qty
Update Qty
Add to Cart
Buy
<-- To get a Freight Estimate, select the options and quantity below and CLICK this button
  • Detailed Description
    GeneratorJoe Avtron Portable Load Banks

    Portable Load Banks for Testing Generators, UPS and Battery Systems.

    Load Banks Direct has assembled a team of load bank industry experts (with over 100 years of combined experience) along with the financial backing of Powerohm Resistors (America’s largest manufacturer of power resistors) to bring you the finest load bank products and support available anywhere.

    We now offer a complete line of standard and custom load banks including freestanding (outdoor stationary) load banks, portable load banks (with caster wheels), radiator mounted load banks or mobile load banks (trailer mounted or containerized).

    All our load banks are 100% Made in the USA, complete with user-friendly controls and many improvements over load banks typically found in the industry today.

    Each LBD load bank is constructed of heavy gauge galvanized steel with polyester powder coat paint to achieve a durable, long-lasting finish. Portability and ease of positioning are provided with moving handles and heavy-duty casters. Tie-down provisions allow for secure transportation to and from job sites.

     


    Resistive Elements

    The resistive load sections feature LBD’s PowerDyne™ wound load elements, fully supported across their entire length within the air stream on stainless steel support rods with high-temperature ceramic insulators.

    Load stability is optimized by maintaining conservative resistor designs.

    The load bank control panel is mounted in a NEMA-12 control enclosure which is suitable for remote mounting and comes standard with each load bank assembly.


    Safety Features

    Each load bank also includes many important safety features such as fused load steps, blower air-fail switch, exhaust over-temperature switch, blower motor overload protection and appropriate warning and caution signage located on the load bank access panels.
    Our freestanding load banks are designed for outdoor, stationary installation and feature fork-lift channels in the

    base for easy installation and lifting.

    Power Connections - Quick Connects

    Portable load banks are equipped with a set of fully-rated, industry exclusive Cam-Lok power connectors which are color coded.

    Fan These load banks have screened cold-air intake and screened/louvered hot-air exhaust for superior all-weather protection and for personnel safety.  All exterior fasteners are stainless steel for long life.

    Each load bank features a high performance blower system, optimally designed for maximum cooling.

    Our portable load banks include heavy duty caster wheels and are designed for temporary indoor operation or rental service.


     


    Connections
    Our standard portable load banks include power capacities ranging from 100 kilowatts to 700 kilowatts with standard load step resolution of 10 kW.

    These load banks are typically used for high power load testing of emergency power systems including generators, uninterruptible power supplies, turbines, battery systems and regenerative power absorption of large motors and other load applications. Our standard freestanding load banks include power capacities ranging from 50 kilowatts to 2500 kilowatts with standard load step resolution of 25 kW.

    Optional 5 kW resolution is available for applications requiring ultra-precision load adjustment. These load banks are suitable for use on all common 50 and 60 hertz power systems up to 600 volts. Custom ratings, DC Load Banks or medium-voltage designs are also available – please contact us at GeneratorJoe at (707) 542-2224 or write sales@generatorjoe.net.

    .Portable Load Bank Features

    Control Power
    A detachable line cord is provided to deliver the convenient 120 Volt AC, 1-phase, 60 Hertz power necessary for control circuit operation. When 120 VAC control power is not readily available, units can be provided with a control power transformer.

    Cooling System
      Integrally mounted blower motors with high-performance, direct-driven fan blades deliver the required airflow volume (CFM) for cooling resistor load elements
      Blower motors operate at 120 VAC, 1-phase, 60 Hertz – line cord provided.
      Motor circuit is short-circuit protected by current-limiting fuses and thermally protected by overload relays
     

    Dual Voltage units feature an operator Blower Voltage Selector switch.

    Digital Power Meter
    A fully equipped, 3-phase Digital Power Metering System that measures a standard range of 16 load parameters. Includes RS485 (Modbus protocol) for remote reading - compatible with PC, PLC, and data loggers.

    Operator Protection
    The LP100 comes equipped with an Emergency-Stop push button allowing the operator to take the unit off-line should a critical hard-stop condition occur. Branch circuit fuse protection provides short-circuit fault protection of all load steps eliminating the potential for catastrophic failure. Blower On, Motor Overload, Air-Flow Failure, and Over-temperature circuits disable all load steps during a fault condition with operator visual indicators, while a Wrong Voltage Applied protection circuit prevents the application of 480 VAC with the Load Voltage Selector switch in the 240 VAC position. The Load Dump circuit provides the operator visual indication if all load steps have been removed.

    Operator Controls Connection Panel Remote Digital Readout LP100 Top Mounted Control Panel
    Emergency Stop (E-Stop)
      Illuminated Main Power On/Off switch
      Blower Voltage Selector switch
      Fan-Phase Reversal switch
      Load Voltage Selector switch (dual voltage units)
      Master Load On/Off switch
      Fault condition smart indicators
      Load Bank Connection Panel - Cam-Lok DIgital Power Meter - Remote Panel Operator Controls - Top Mounted High Visibility
    GENERATORJOE LOAD BANKS DIRECT - PORTABLE LOAD BANKS
    GeneratorJoe LBD
    Part Number
    Power Rating
    (kW)
    Load Voltage
    (VAC)
    Amp Per Phase Load Step Blower Motor
    HP
    Blower Motor Voltage
    (VAC)
    Dimentions
    Inches  [mm]
    Weight
    lbs. [kg]
    LP100-240-480-10M 90/100 240/480 216/120 10 0.5 120 15”W x 30”D x 30”H [380 x 760 x 760] 115 lbs. [55 kg]
    LP100-480-10M 100 480 120 10 0.5 120 15”W x 30”D x 30”H [380 x 760 x 760] 100 lbs. [45 kg]
    LP100-600-10M 100 600 96 10 0.5 120 15”W x 30”D x 30”H [380 x 760 x 760] 100 lbs. [45 kg]
    LP150-240-480-10M 143.75/150 240/480 346/180 10 0.5 120 27”W x 34”D x 40”H [685 x 860 x 1010] 195 lbs. [90 kg]
    LP150-480-10M 150 480 180 10 0.5 120 27”W x 34”D x 40”H [685 x 860 x 1010] 185 lbs. [85 kg]
    LP150-600-10M 150 600 144 10 0.5 120 27”W x 34”D x 40”H [685 x 860 x 1010] 185 lbs. [85 kg]
    LP200-400-5MT 200 400 289 5 1.5 400 27W x 34”D x 48”H [685 x 860 x 1220] 295 lbs. [135 kg]
    LP250-240-480-10M 243.75/250 240/480 586/300 10 1 120 27”W x 34”D x 55”H  [685 x 860 x 1400] 295 lbs. [135 kg]
    LP250-480-10M 250 480 300 10 1 120 27”W x 34”D x 55”H  [685 x 860 x 1400] 280 lbs. [130 kg]
    LP250-600-10M 250 600 241 10 1 120 27”W x 34”D x 55”H  [685 x 860 x 1400] 280 lbs. [130 kg]
    LP400-240-480-5MT 400 240/480 962/481 5 3 230 or 460 34”W x 49”D x 63”H  [860 x 1240 x 1600] 850 lbs.  [385 kg]
    LP400-480-5MT 400 480 481 5 3 460 34”W x 49”D x 63”H  [860 x 1240 x 1600] 850 lbs.  [385 kg]
    LP400-600-5MT 400 600 385 5 3 575 34”W x 49”D x 63”H  [860 x 1240 x 1600] 850 lbs.  [385 kg]
    LP400-400-5MT 400 400 577 5 5 400 34”W x 49”D x 63”H  [860 x 1240 x 1600] 850 lbs.  [385 kg]
    LP500-240-480-5MT 497.5/500 240/480 1197/601 5 5 230 or 460 34”W x 49”D x 63”H  [860 x 1240 x 1600] 900 lbs.  [410 kg]
    LP500-480-5MT 500 480 601 5 5 460 34”W x 49”D x 63”H  [860 x 1240 x 1600] 875 lbs.  [400 kg]
    LP500-600-5MT 500 600 481 5 5 575 34”W x 49”D x 63”H  [860 x 1240 x 1600] 875 lbs.  [400 kg]
    LP500-400-5MT 500 400 722 5 7.5 400 34”W x 49”D x 63”H  [860 x 1240 x 1600] 900 lbs.  [410 kg]
    LP600-240-480-10MT 487.5/600 240/480 1173/722 10 5 230 or 460 34”W x 49”D x 63”H  [860 x 1240 x 1600] 900 lbs.  [410 kg]
    LP600-480-10MT 600 480 722 10 5 460 34”W x 49”D x 63”H  [860 x 1240 x 1600] 875 lbs.  [400 kg]
    LP600-600-10MT 600 600 577 10 5 575 34”W x 49”D x 63”H  [860 x 1240 x 1600] 875 lbs.  [400 kg]
    LP800-480-5MT 800 480 962 5 10 460 34”W x 49”D x 77”H  [860 x 1240 x 1950] 1250 lbs.  [570 kg]
    LP800-600-5MT 800 600 770 5 10 575 34”W x 49”D x 77”H  [860 x 1240 x 1950] 1250 lbs.  [570 kg]
    LP800-400-5MT 800 400 1155 5 10 400 34”W x 49”D x 77”H  [860 x 1240 x 1950] 1300 lbs.  [590 kg]
    LP850-240-480-5MT 600/850 240/480 1443/1022 5 10 230 or 460 34”W x 49”D x 77”H  [860 x 1240 x 1950] 1300 lbs.  [590 kg]
    LP1000-480-10MT 1000 480 1202 10 10 460 34”W x 49”D x 77”H  [860 x 1240 x 1950] 1300 lbs.  [590 kg]
    LP1000-600-10MT 1000 600 962 10 10 575 34”W x 49”D x 77”H  [860 x 1240 x 1950] 1300 lbs.  [[590 kg]
  • This product does not have designated product packages.

    Please see the Priced Options tab and select the options you want supplied with the product. Prices will update automatically when you select or remove an option.

  •  
    Purchase option only
    Stationary Load Banks Details
    Load Leveler Details
    Power Meter Details
    Step Resolution Details
  • Standard Features
    Stationary Load Banks, Single & Three Phase,
    Outdoor Weatherproof Construction
    Rated for Continuous Duty with No Cool-down Period
    Highest Capacity in the Smallest Installed Footprint
    Branch Circuit Fusing Virtually Eliminates Catastrophic Failure
    Slide Out Resister Case Assemblies
    Intelligent Safety Circuits, Indicators &Operator Controls
    Galvanized Steel with the Highest Quality Durable Powder-coat Paint Finish.
    Portability & Ease of Positioning
    Cam-Lok Power Connectors
    Protective Snap-back Covers
    PowerDyne™ Resistors
    Stainless Steel Support Rods
    Heavy-Duty, High-Temperature Ceramic Insulators
    Fully Equipped, 3-Phase Digital Power Metering System
    Measures a sSandard Range of 16 Load Parameters
    RS485 (Modbus protocol) for Remote Reading
    Intelligent Operator Controls, Safety Indication Layouts, Adjustable Load Step Resolution
    Emergency-Stop Push Button
    Blower On, Motor Overload, Air-Flow Failure, and Over-temperature Circuits
  • To get started with a lease, click the button below.

    Lease Info

  • To search for other products click the button below.

    Search

  • To find transfer switches click the button below.

    Transfer Switches

General Notes: Proudly made in the USA by Americans!